Murata Manufacturing has begun mass production of two new anisotropic magnetoresistance (AMR) sensors designed for healthcare, wearable and IoT devices, targeting the growing demand for longer battery life in compact, coin cell-powered systems.
The two sensors – the MRMS166R and MRMS168R – are solid-state magnetic sensors built for switching applications. They detect the presence or absence of a magnetic field and generate an output signal that system logic can use to control functions such as transitions between active and sleep modes.
The MRMS166R is the first AMR sensor to combine an average current consumption of 20 nA with operation from a 1.2 V supply, according to Murata.
Addressing battery constraints in compact devices
Automatic switching between active and sleep modes is a common feature in battery-powered devices, used to reduce standby power consumption and extend operating life. In healthcare, the applications include capsule endoscopes and medical patches. Wearable devices such as AR glasses and wireless earbuds also rely on this functionality, as do security-related IoT devices like door open/close detection systems and smart locks.
These devices commonly use silver oxide coin batteries, which typically operate at 1.55 V and impose constraints on both available capacity and operating voltage. AMR sensors used as magnetic switches must therefore minimise current consumption while maintaining stable operation at low voltage.
Murata addressed these requirements through a redesign of the AMR sensor’s internal circuitry, enabling low current consumption and reliable operation down to 1.2 V. The company indicated this reduces battery consumption during standby operation, supporting device operation for more than two years in typical use.
Compact design for space-constrained applications
Both devices are housed in a package measuring 1.0 x 1.0 x 0.4 mm, making them suitable for space-constrained designs where every fraction of a millimetre counts.
The MRMS166R operates over a 1.2 to 3.6 V supply range, with a typical voltage of 1.5 V. It draws an average current consumption of 20 nA and delivers a maximum current output of 1 mA.
The MRMS168R, meanwhile, operates over a 2.0 to 3.6 V supply range with a typical voltage of 3.0 V. It draws an average current consumption of 80 nA and delivers a maximum output current of 12 mA, providing higher output drive capability for devices requiring increased load current.
Contactless switching removes mechanical wear points
The sensors use contactless switching rather than mechanical components. This approach improves reliability and supports sealed, miniaturised designs – an important consideration in medical and wearable applications where device integrity is critical.
By removing the need for physical contact in the switching mechanism, the sensors help reduce potential failure points and allow for smaller form factors in devices that may need to operate in challenging environments or be worn on the body for extended periods.
Broader sensor lineup planned
Murata indicated it will continue to expand its AMR sensor lineup and reduce power consumption to support longer operating times and expanded functionality in medical, wearable and IoT devices.
The Kyoto-based company, listed on the Tokyo Stock Exchange, is a manufacturer of ceramic-based passive electronic components and solutions, communication modules and power supply modules. Murata operates manufacturing facilities worldwide.
Last Updated on April 27, 2026 by Nick Ross